Icon Crear Crear
Obtener Plan Académico
Obtener Plan Académico
Obtener Plan Académico

Instrumentation II (3/3)

Test

Multiple choice

Descarga la versión para jugar en papel

Edad recomendada: 16 años
3 veces realizada

Creada por

Estados Unidos

Top 10 resultados

  1. 1
    04:59
    tiempo
    94
    puntuacion
¿Quieres aparecer en el Top 10 de este juego? para identificarte.
Crea tu propio juego gratis desde nuestro creador de juegos
Compite contra tus amigos para ver quien consigue la mejor puntuación en esta actividad

Top juegos

  1. tiempo
    puntuacion
  1. tiempo
    puntuacion
tiempo
puntuacion
tiempo
puntuacion
 
game-icon

Instrumentation II (3/3)Versión en línea

Multiple choice

por Joshua Liberty
1

When image data is represented in terms such as counts per pixel or X,Y data, this data is said to exist in the ?

2

What does the order do in a Butterworth filter?

3

The maximum frequency the filter will pass is called?

4

The camera stays close to more of the patient's body, using body mapping to move heads in and out before scan starts; this is called?

5

All data needed to reconstruct one trans axial slice is?

6

The process of creating transaxial slices from the projection views is?

7

Elliptical orbits would have ?

8

_____ s represented by high frequencies (HF), which are to some degree separate from the frequencies that related to the _______.

9

The ramp filter is a _____ pass filter.

10

What causes start artifact in SPECT processing?

11

What is found in the low frequencies?

12

What is found in the mid frequencies?

13

What is found in the high frequencies?

14

A Nyquist frequency of 1.0 is used; the result will be ?

15

If Nyquist is expressed in _______, the number values is based on ____.

16

This 3D technique uses solid model of the exterior pixels, hiding the interior pixels from view, uses shading to make known shape of object. This is?

17

This 3D technique reprojects 3D image matrix, creating 2D projections, views in a rotating cine display like a movie?

18

This 3D technique uses hottest voxel along each ray to generate projection?

19

The Nyquist frequency is?

20

How does FBP help get rid of streaks from backprojection?

21

All filtering is a compromise between ____ and _______.

22

Why is COR done?

23

Name reasons for a Moire artifact?

24

When a source is moved from edge to center of a PMT, the light collection efficiency of that PMT increases more rapidly than the distance the source is moved; this causes image of a line source crossing in front of a PMT to be bent toward the center; this is called?

25

A SPECT resolution and uniformity test is needed; the phantom needed is?

26

Imposing a digital format on an analog image, a photon on border of 2 pixels must be assigned to one or another. This is called?

27

Tl-201 cardiac study would be processed with a ____ filter with a ___ cut off frequency.

28

A tech wants a study with high resolution and is willing to accept noise; which filter is best?

29

What is inverse Fourier transform used for in SPECT?

30

A well counter is checked for % energy resolution with both Tc99m and Cs-137; the Tc99m result is 12% and Cs-137 result is 6%; what can be concluded?

31

______ is the essence of CT and X-ray imaging?

Feedback

Count poor study

educaplay suscripción