Fire and Life Safety Building Services Game (24)

Sí o No

(6)
Test your knowledge on the fire and life safety aspects of building services with this interactive game!

Descarga la versión para jugar en papel

131 veces realizada

Creada por

Estados Unidos
Este juego es una version de

Top 10 resultados

  1. 1
    01:03
    tiempo
    95
    puntuacion
  2. 2
    Vincent Lovato
    Vincent Lovato
    02:25
    tiempo
    90
    puntuacion
  3. 3
    01:59
    tiempo
    80
    puntuacion
  4. 4
    Guillermo
    Guillermo
    02:00
    tiempo
    60
    puntuacion
¿Quieres aparecer en el Top 10 de este juego? para identificarte.
Crea tu propio juego gratis desde nuestro creador de juegos
Compite contra tus amigos para ver quien consigue la mejor puntuación en esta actividad

Top juegos

  1. tiempo
    puntuacion
  1. tiempo
    puntuacion
tiempo
puntuacion
tiempo
puntuacion
 
game-icon

Fire and Life Safety Building Services Game (24)Versión en línea

Test your knowledge on the fire and life safety aspects of building services with this interactive game!

por Suzanne Freeman
1

Utility chases can be used for plumbing, electrical raceways, telecommunications, data cables, and HVAC ductwork.

2

Vertical shafts are primarily used for storage of flammable materials.

3

Building services are designed to provide safety, comfort, and convenience for occupants.

4

Grease ducts are typically installed over cooking appliances and carry grease vapors to the outside of a building.

5

The use of a fire-resistive-rated duct wrap system can accomplish the 1-hour fire-resistive separation requirement.

6

Kitchen grease exhaust ducts always require 1-hour fire-resistive separation.

7

Grease ducts are not necessary for all cooking appliances.

8

Commercial cooking venting systems may require automatic fire suppression equipment.

9

Grease ducts are made of combustible materials.

10

Refuse and linen chutes are not required to be constructed of fire-resistive construction.

11

Building services are designed to create fire hazards within a building.

12

Elevator hoistways are equipped with fire-rated door assemblies.

13

Refuse and linen chutes are required to be constructed of fire-resistive construction and may require sprinkler protection.

14

Utility chases are occupied spaces within a building.

15

Hoistways are constructed of combustible materials and do not have fire-rated door assemblies.

16

Defective subsystems have no effect on the overall building system.

17

Wiring, ductwork, and piping should be run within the elevator hoistway.

18

Kitchen grease exhaust ducts do not require any fire-resistive separation.

19

Proper installation of grease ducts ensures that grease does not become trapped and cause a fire.

20

Subsystems must be appropriately installed, inspected, tested, and maintained to ensure building system safety.